One precise form of heighht sensing uses a non-contact laser beam to
regulate the height of the dispensing tip from the receiving surface,
as indicated in figure 6. The laser sensor automatically corrects for
warp and thickness variations on a dot-by-dot basis. It emits a beam
at the time of dispensing that reflects back from the receiving surface.
This is checked in the systems computer against preprogrammed coordinates.
If the height does not match the required coordinates, the sensor instructs
the system to correct to correct the distance of the dispensing tip
above the receiving surface. The required adjustment is made and the
system continues dispensing. All in less that 10 µs. All calculations
and adjustments are accomplished "on-the-fly" during the actual
moment of dispense. With dots of solder paste in the volume range of
0.01 µl, even a minute height variance can be crucial to successful
dispensing.
This type of sensor is not always needed, but this is a good option
to keep in mind. If the hybrids are always flat the automated height
correction is not needed. If there is a chance that uneven height may
be present, it is a worthwhile option to have.
|
|
Conclusion
Hybrid assemblies come in a multitude of sizes and configurations and
are relatively small when compaired to other types of printed circuit
assemblies. For substrates on the larger size end of the scale and for
those requiring less dense solder paste patterns and larger dots, screening
can handle the application. When the size of the hybrid drops and the
density of the dispense pattern increases, both size and placement of
solder paste patterns become critical.
Most types of automated positioning systems for dispensing can give
the speed and programmability needed. Figure 7 shows an example of a
fully equiped automated dispensing system. A proper vision alignment
system will make sure that the dispensing is repeatable in pattern positioninghg
and if required, a non-contact height sensor will ensure the hybrid
receiving surface is level in relation to the dispensing tip. However,
due to the size of the substrates involved and the idiosyncrasies of
the material itself, when dispensing solder paste only the most precise
dispensing head can give the ability to accomplish repeatable, volumetric
dispensing after all other parameters have been met.
|
|

Figure 6 a laser guide height sensor

Figure 7, ADM-1812/TS benchtop automated dispensing system with piston
positive displacement pump, vision alignment system, and a laser height
sensor.
|